Conventional Surface Well Testing
Since inception FarleyRiggs has delivered a comprehensive range of well testing services to meet various client requirements including, but not limited to, temporary well test packages, extended well test packages and depressurisation packages.
Our commitment is to deliver high levels of service quality while ensuring innovative solutions help clients deliver on operational objectives.
At FarleyRiggs we believe that acquiring accurate and adequate data during well test activities is the key to success. FarleyRiggs has added to its product portfolio a state of the art data acquisition system to enable real time acquisition, rate calculation and trend analysis.
We continue to develop our capability to provide project management services. The ability to deliver both experience and expertise to client projects is seen as a key area of our well test service capability.
We believe that people are the key to delivering high levels of service quality. As such FarleyRiggs is committed to developing personnel through training from both internal and external sources.

FarleyRiggs will continue to develop innovative well test and project management solutions. Our commitment is to be ready and available when clients require our expertise and services.
Unconventional Surface Well TestingThe Bear Cyclone Separator uses a newly developed Gas-Liquid Cylinder Cyclone (GLCC) technology that greatly reduces size and pressure drop compared with standard separators. The GLCC are designed for various levels of well performance. The momentum of the inlet process fluid generates a liquid vortex that allows sufficient gas and liquid separation to rapidly occur. This process creates dryer gas, lower pressure drop, and generally leads to a smaller equipment footprint.
Advantages;
Technology Applications;
GLCC Flow Range
| Flowing Pressure | 6" GLCC Flow | 8" GLCC Flow | 10" GLCC Flow | ||||
|---|---|---|---|---|---|---|---|
| PISG | KPAG | Mscf/d | e3m3/d | Mscf/d | e3m3/d | Mscf/d | Mscf/d |
| 5 | 34 | 400 | 11.4 | 650 | 18.4 | 1000 | 28.4 |
| 10 | 69 | 500 | 14.1 | 725 | 20.5 | 1200 | 33.9 |
| 20 | 138 | 600 | 17.1 | 850 | 24.1 | 1450 | 41.6 |
| 50 | 345 | 700 | 19.8 | 1000 | 28.4 | 2200 | 60 |
| 100 | 689 | 1000 | 28.4 | 1300 | 36.8 | 2800 | 79.8 |
| 200 | 1379 | 1600 | 45.3 | 1900 | 54 | 3800 | 108.1 |
| 300 | 2068 | 2200 | 60 | 2500 | 71.5 | 4800 | 136.3 |
| 400 | 2758 | 2800 | 79.8 | 3100 | 87.2 | 5800 | 164.6 |
| 500 | 3447 | 3400 | 96.8 | 3700 | 103.9 | 6800 | 192.8 |
| Inlet Pipe Size | Sep Pressure Drop | Sep Pressure Drop | Sep Pressure Drop | ||||
| 2" Inlet | < 1.3 psi | < 2 psi | < 2 psi | ||||
| 3" Inlet | < 1 psi | < 1 psi | |||||
| 4" Inlet | < 0.3 psi | < 0.3 psi | |||||
Surface Well Test Data Acquisition
Pressure Sensors
| Pressure Range: | 6,000 psi |
| Pressure Accuracy: | 0.024% Full Scale |
| Pressure Resolution: | 0.0003% Full Scale |
| Pressure Drift: | < 3 psi / yr |
External Temperature
| Temp Accuracy: | 0.4°C |
| Temp Repeatability: | < 0.1°C |
| Temp Resolution: | < 0.05°C |
PEAK delivers the assurance that data acquired during the test is complete and accurate enabling instantaneous calculation of rate data.
The ability to trend real time data delivers the added benefit of being able to instantaneously assess well performance. Trending is also an important tool to enable potential problems to be dealt with at an early stage of recognition.
Surface Acquisition System Specification;
Surface Data Acquisition System Features;